Maximum Floor Load Width (mm)Select all inputs above
Select wind, grade, stud spacing and joist spacing above.
Table 44 Notes
Maximum floor load widths are based on a maximum flooring plus ceiling mass of 40 kg/m².
Studs for internal non-loadbearing bracing walls and partitions (not carrying floor or roof loads) shall be as per Clause 6.3.5.
Edge distances for some sheet bracing materials may require a minimum stud width of 45 mm for joining sheets.
Large stud sizes may be made up by vertical nail lamination as per Clause 2.4.
Notch depth is 20 mm maximum.
Engineering Disclaimer —
For preliminary assessment only. Verify all results with a suitably qualified structural engineer before use.
Always consult the current edition of AS 1684.2 and applicable building codes.
Structopedia accepts no liability for errors or reliance on outputs.
Clause reference: AS 1684.2 Cl. 6.3.4 · Table 44