AS 1684.2 · Timber Framing
Table 7 · Wall Studs
Selections
Wind
Grade
Stud sp.
Roof
Rafter sp.
Table 7
WALL STUDS – Not notched – Single or upper storey
AS 1684.2 — Cl. 6.3.3 Single & Upper Storey

Figure 6.12 — Wall studs

Show ▼
AS 1684.2 Figure 6.12 — Wall studs
Wind classification
Timber grade
Stud spacing
Roof type
Rafter / truss spacing
mm — highlights passing sizes

Table 7 — Wall Stud max RLW

Size D×B (mm) Stud height (mm) Max RLW (mm)

Table 7 — Notes

  1. Maximum RLW based on sheet roof 40 kg/m² and tile roof 90 kg/m² (incl. framing and ceiling mass).
  2. Studs for internal non-loadbearing bracing walls and partitions (not carrying roof loads) shall be as per Cl. 6.3.5.
  3. Edge distances for some sheet bracing materials may require a minimum stud width of 45 mm for joining sheets.
  4. Large stud sizes may be made up by vertical nail lamination per Cl. 2.4.
  5. All stud walls shall be nogged at not greater than 1350 mm centres.
  6. Maximum tension load for tie-down: 8.5 kN per stud or nail-laminated laminate.
  7. For design parameters refer to Figure 6.12.
Disclaimer: This calculator references span tables from AS 1684.2 Supplements (2010). Results are for guidance only and must be verified by a suitably qualified engineer or building designer against the current edition of the Standard and project-specific conditions. Structopedia accepts no liability for errors or omissions.